ILD-200 Advanced Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. We set out to develop the best refrigerant leak detector for HVACR. The Six-hour battery life lets you work all day before recharging. The sound and light alarm allows you to work the way you want to work. This infrared leak detector allows it to detect even the most difficult ones like R-134a, R-404A, R-407C, R-410A and 1234yf refrigerants. Our exclusive solid electrolyte sensor technology reduces heat and gives the sensor a longer life than traditional heated diode or corona detectors.
Sensor Life | 10 years |
Max Sensitivity | 0.14 oz/yr |
Response Time | ≤ 1s |
Preheating Time | 30s |
Refrigerant Types | CFC/HFC/HCFC/HFO |
Package Included | 1 x Leak Detector, 1 x Packet of Filters, 1 x USB Cable, 1 x UV light |
Screen | 2.8" TFT LCD display |
Auto OFF | 10 minutes without operation |
Operating Temperature | -10°C to 52°C (14°F to 125.6 °F) |
Operating Humidity | 50%~85%RH |
Storage Temperature | -20°C to 60°C (-4°F to 140 °F) |
Weight | 0.93 ibs |
Size | 7.9*3.3*1.5 inches |
Battery | 3.7V 3000mAh rechargeable lithium battery, full charge for 6 hours continuous work |
Application of Infrared Technology Improves the Accuracy of Your Detection
Advanced Refrigerant Leak Detector, Awesome HVAC/R Job Partner
In a noisy environment, connecting it with headphones, make alarm sounds clearly
Anti-interference
More Accurate Detection Results
Minimize false alarms from other chemicals
Pump Suction
No direct-contact with refrigerants. Longer life than heated diode
Detect All Halogenated Refrigerants.
HFCs, HCFCs, CFCs, PFCs, HFOs, HCs.
Reset to max sensitivity in clean air
Reset to current sensitivity in refrigerants environment to detect higher concentration leakages
Q&A
Q: Is it normal for the device to start beeping when turned on?
A: Yes, it beeps upon powering on, and when a leak is detected, the alarm sound becomes more urgent.
Q: Why can't leaks be detected?
A: 1.The product will automatically calibrate within 2 seconds upon detecting a leak. After moving away from the leak point, approach multiple times to determine if there is a leak.
2. Sensor damaged.
3. Air pump has lost suction capability.
4. The internal pipeline is blocked.
Q: Why does the product alarm when not in a leaking environment?
A: 1. Impact triggers false alarm: Deformation of the optical chamber affects detection data, a normal occurrence.
2. False alarm with slight movement: Loose critical optical filters, contact us for repair assistance.
3. Strong magnetic field nearby: Check for routers or devices causing electromagnetic interference.